5V10mA 8 Channels Coin Cell Tester Battery Capacity Testing Machine Equipment
Model: CT-4008Tn-5V10mA-HWX
CT-4008Tn-5V10mA-HWX Coin Cell Tester is an eight-channel battery analyzer to analyze small coin cells with a range current 5μA-10mA, voltage 25mV~5V
Products Description
|
BTS-5V10mA Three-Range Battery Testing System |
|||||
|
Equipment material code |
CT-4008Tn-5V10mA-HWX |
||||
|
Indicator project |
Indicator parameters |
||||
|
Enter the power supply |
AC 220V ±10% / 50Hz |
||||
|
Input active power |
25W |
||||
|
Resolution ratio |
AD: 24bit;DA: 16bit |
||||
|
Input impedence |
≥1GΩ |
||||
|
Voltage |
Constant voltage range control |
25mV~5V |
|||
|
Minimum discharge voltage |
-5V |
||||
|
Accuracy |
± 0.05% of FS |
||||
|
Stability |
0.1% of FS |
||||
|
Current |
Output range per channel |
Range 1: 5μA ~ 1mA; Range 2: 1mA ~ 5mA; Range 3: 5mA ~ 10mA |
|||
|
Accuracy |
± 0.05% of FS |
||||
|
Constant pressure cut-off current |
Range 1: 2μA; Range 2: 0.01 mA; Range 3: 0.02 mA |
||||
|
Stability |
0.1% of FS |
||||
|
Power |
Single-channel maximum output power |
0.25W |
|||
|
Stability |
0.2% of FS |
||||
|
Time |
Current response time (10% FS to 90% FS) |
<500μs |
|||
|
Working step time range |
(365 * 24) hours / work step |
Supported in time format: 00:00:00:00 (h, min, s, ms) |
|||
|
Data logging |
Data recording conditions |
Minimum time interval: 100ms |
|||
|
Minimum voltage interval: 10 mV |
|||||
|
Minimum current interval: range 1:2 uA; range 2:0.01 mA; range 3:0.02 mA |
|||||
|
Record frequency |
10Hz |
||||
|
Charge |
Charging mode |
Constant current charging, constant voltage charging, constant current constant pressure charging, constant power charging |
|||
|
Cut-off condition |
Voltage, current, relative time, capacity, - △ V |
||||
|
Discharge |
Discharge mode |
Constant current discharge, constant voltage discharge, constant current constant voltage discharge, constant power discharge, constant resistance discharge |
|||
|
Cut-off condition |
Voltage, current, relative time, and capacity |
||||
|
Pulse mode |
Charge |
Constant current mode, constant power mode |
|||
|
Discharge |
Constant current mode, constant power mode |
||||
|
Minimum pulse width |
500ms |
||||
|
Pulse number |
A single pulse work step supports 32 different pulses |
||||
|
Continuous charge / discharge charge switching |
A pulse step can realize charging continuous switching, or discharge continuous switching; (charge-to-charge switching is not supported) |
||||
|
Cut-off condition |
Voltage, and relative time |
||||
|
DCIR test |
Support for custom taking points for the calculation of DCIR |
||||
|
Recurrence |
Circulating test range |
1 to 65,535 times |
|||
|
Single cycle step number |
254 |
||||
|
Loop nesting |
With a nesting cycle function, up to a 10-layer nesting support |
||||
|
Protect |
● Power-loss data protection |
||||
|
● It has the offline test function |
|||||
|
● Safety protection conditions can be set, setting parameters include: voltage limit, voltage limit, current limit, current limit, capacity limit, delay time |
|||||
|
IP levels of protection |
Protection level is IP20 |
||||
|
Channel characteristics |
The constant current source and the constant voltage source adopt a double closed-loop structure |
||||
|
Channel control mode |
Independent control |
||||
|
Voltage and current detection and sampling |
Four-line connection |
||||
|
Noise |
<45dB |
||||
|
Data base |
The MySQL database was used to centralize the test data |
||||
|
Upper-computer communication mode |
Based on the TCP / IP protocol |
||||
|
Server operating system |
Windows 7 / Windows 10 and above systems |
||||
|
Data output mode |
EXCEL2003,2010,TXT |
||||
|
Server disk configuration |
500GB |
||||
|
CI |
Internet access |
||||
|
Leakage current |
0.005μA |
||||
|
Number of machine channels |
8 |
||||
|
Equipment working environment requirements |
|||||
|
Indicator project |
Indicator parameters |
||||
|
Operating temperature range |
0℃~40℃; Ensure the measurement accuracy within the calibration temperature (usually 25℃) plus or minus 5℃; Accuracy drift is 0.005% of FS /℃ |
||||
|
Storage temperature range |
-10℃~50℃ |
||||
|
Relative humidity range of the working environment |
70% RH (no moisture condensation) |
||||
|
Storage environment relative humidity range |
80% RH (no moisture condensation) |
||||
|
Grilamp specifications and dimensions |
|||||
|
Indicator project |
Indicator parameters |
||||
|
Types of fixtures |
Up and down fixtures |
||||
|
Clip image |
|
|
|
||
|
Crocodile fixtures |
Polymer fixtures |
PCB buckle fixture |
|||
|
Pictures are for reference only, subject to the physical object |
|||||
|
Case size per unit (W * D * H) (mm) |
1U(19"), 483*310*48 |
||||
|
Device picture |
|
||||
|
Pictures are for reference only, subject to the physical object |
|||||
Hot Tags: 5v10ma 8 channels coin cell tester, China 5v10ma 8 channels coin cell tester manufacturers, suppliers, factory, Battery Electrode Coating, Battery NMP System, Transfer Coating System, Laboratory Viscometer, slurry mixing tank, Pouch Cell Electrode Die Cutting Machine